Aluminium Armoured Cable

Leading Wholesale Distributor of 4sqmm 4 core aluminum armoured cables, 6 sq mm 4 core aluminum armoured cable, 10 sqmm 4 core aluminium armoured cable, 16 sq mm 4 core aluminum armoured cable, 25 sq mm 4 core aluminum armoured cable and 35 sq mm 4 core aluminum armoured cable from Rau.

4Sqmm 4 Core Aluminum Armoured Cables

4Sqmm 4 Core Aluminum Armoured Cables
  • 4Sqmm 4 Core Aluminum Armoured Cables
Get Best Quote
Approx. Price: Rs 96.14 / MeterGet Latest Price

Product Details:

BrandV-Marc
Number of Cores4 Core
Conductor Size4 sq. mm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

6 Sq Mm 4 Core Aluminum Armoured Cable

6 Sq Mm 4 Core Aluminum Armoured Cable
  • 6 Sq Mm 4 Core Aluminum Armoured Cable
Get Best Quote
Approx. Price: Rs 121.91 / MeterGet Latest Price

Product Details:

BrandV-marc
Number of Cores4 Core
Conductor Size6 sq. mm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

10 Sqmm 4 Core Aluminium Armoured Cable

10 Sqmm 4 Core Aluminium Armoured Cable
  • 10 Sqmm 4 Core Aluminium Armoured Cable
Get Best Quote
Approx. Price: Rs 155.54 / MeterGet Latest Price

Product Details:

BrandV-marc
Number of Cores4 Core
Conductor Size10 sq. mm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

16 Sq Mm 4 Core Aluminum Armoured Cable

16 Sq Mm 4 Core Aluminum Armoured Cable
  • 16 Sq Mm 4 Core Aluminum Armoured Cable
Get Best Quote
Approx. Price: Rs 166.28 / MeterGet Latest Price

Product Details:

BrandV-Marc
Number of Cores4 Core
Conductor Size16 sq. mm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

25 Sq Mm 4 Core Aluminum Armoured Cable

25 Sq Mm 4 Core Aluminum Armoured Cable
  • 25 Sq Mm 4 Core Aluminum Armoured Cable
Get Best Quote
Approx. Price: Rs 234.58 / MeterGet Latest Price

Product Details:

BrandV-marc
Number of Cores4 Core
Conductor Size25 sq. mm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

35 Sq Mm 4 Core Aluminum Armoured Cable

35 Sq Mm 4 Core Aluminum Armoured Cable
  • 35 Sq Mm 4 Core Aluminum Armoured Cable
Get Best Quote
Approx. Price: Rs 303.63 / MeterGet Latest Price

Product Details:

BrandV-Marc
Number of Cores4 Core
Conductor Size35 sq. mm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

70 Sq Mm 3.5 Core Aluminum Armoured Cable

70 Sq Mm 3.5 Core Aluminum Armoured Cable
  • 70 Sq Mm 3.5 Core Aluminum Armoured Cable
Get Best Quote
Approx. Price: Rs 486.34 / MeterGet Latest Price

Product Details:

BrandV-marc
Number of Cores3.5 Core
Conductor Size70 Sqmm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

95Sqm 3.5 Core Aluminum Armoured Cable

95Sqm 3.5 Core Aluminum Armoured Cable
  • 95Sqm 3.5 Core Aluminum Armoured Cable
Get Best Quote
Approx. Price: Rs 687.23 / MeterGet Latest Price

Product Details:

BrandV-Marc
Number of Cores3.5 Core
Conductor Size70 sq. mm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

120 Sq Mm 3.5 Core Aluminum Armoured Cable

120 Sq Mm 3.5 Core Aluminum Armoured Cable
  • 120 Sq Mm 3.5 Core Aluminum Armoured Cable
Get Best Quote
Approx. Price: Rs 763.88 / MeterGet Latest Price

Product Details:

BrandV-marc
Number of Cores3.5 Core
Conductor Size120 sq. mm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

150sq Mm 3.5 Core Aluminum Armoured Cable

150sq Mm 3.5 Core Aluminum Armoured Cable
  • 150sq Mm 3.5 Core Aluminum Armoured Cable
Get Best Quote
Approx. Price: Rs 905.29 / MeterGet Latest Price

Product Details:

BrandV-marc
Number of Cores3.5 Core
Conductor Size150 sq. mm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

185 sqmm 3.5 core Aluminum Armoured Cable

185 sqmm 3.5 core Aluminum Armoured Cable
  • 185 sqmm 3.5 core Aluminum Armoured Cable
Get Best Quote
Approx. Price: Rs 1,146.15 / MeterGet Latest Price

Product Details:

BrandV-marc
Number of Cores3.5 Core
Conductor Size185 sq. mm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

300 Sqmm 3.5core Aluminium Armoured Cable

300 Sqmm 3.5core Aluminium Armoured Cable
  • 300 Sqmm 3.5core Aluminium Armoured Cable
Get Best Quote
Approx. Price: Rs 1,770.94 / MeterGet Latest Price

Product Details:

BrandV-marc
Number of Cores3.5 Core
Conductor Size300 sq. mm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

400Sqmm 3.5 Core Alumium Armoured Cable

400Sqmm 3.5 Core Alumium Armoured Cable
  • 400Sqmm 3.5 Core Alumium Armoured Cable
Get Best Quote
Approx. Price: Rs 2,262.24 / MeterGet Latest Price

Product Details:

BrandV-marc
Number of Cores3.5 Core
Conductor Size400 sq. mm
Insulation MaterialXLPE
Armouring TypeSteel Flat Strip
Voltage Rating1.1 kV
Conductor MaterialAluminium
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.