Lumens Electrical
Lumens Electrical
Rau, Indore, Madhya Pradesh
GST No. 23AGGPJ9567R1ZJ
TrustSEAL Verified
Call 08047620204 57% Response Rate
SEND EMAIL

Armoured Cable

We are a leading Wholesale Distributor of 240sqmm 3.5core aluminum armoured cable, 50 sq mm 3.5 core aluminum armoured, 6 sqmm 3 core copper armoured cable, 10 sq mm 3 core copper armoured cable, 16 sq mm 3 core copper armoured cable and 2.5 sqmm x 2 core copper armoured cable from Rau, India.

240sqmm 3.5Core Aluminum Armoured Cable

240sqmm 3.5Core Aluminum Armoured Cable
  • 240sqmm 3.5Core Aluminum Armoured Cable
Get Best Quote
Approx. Price: Rs 1,439 / MeterGet Latest Price

Product Details:

Conductor Size240 sqmm
Cable Length500 m
Voltage Grade1.1 KV
Insulation MaterialXLPE
Conductor MaterialAluminium

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

50 Sq Mm 3.5 Core Aluminum Armoured

50 Sq Mm 3.5 Core Aluminum Armoured
  • 50 Sq Mm 3.5 Core Aluminum Armoured
Get Best Quote
Approx. Price: Rs 360.79 / MeterGet Latest Price

Product Details:

Conductor Size3.5 sqmm
Cable Length500 m
Voltage Grade1.1KV
Conductor MaterialAluminium
Insulation MaterialXLPE
Armour TypeAluminium Strip
Cable ShapeRound
Outer SheathPVC
Core ColourStandard
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

6 Sqmm 3 Core Copper Armoured Cable

6 Sqmm 3 Core Copper Armoured Cable
  • 6 Sqmm 3 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 322.14 / MeterGet Latest Price

Product Details:

Conductor Size6 sqmm
Cable Length500 m
Voltage Grade1.1KV
Conductor MaterialCopper
Insulation MaterialPVC
Armour TypeAluminium Strip
Cable ShapeRound
Outer SheathPVC

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

10 Sq Mm 3 Core Copper Armoured Cable

10 Sq Mm 3 Core Copper Armoured Cable
  • 10 Sq Mm 3 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 514.43 / MeterGet Latest Price

Product Details:

Conductor Size10 sqmm
Cable Length500 m
Voltage Grade1.1KV
Conductor MaterialCopper
Insulation MaterialPVC
Armour TypeGI Steel Wire
Cable ShapeRound
Outer SheathPVC
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

16 Sq Mm 3 Core Copper Armoured Cable

16 Sq Mm 3 Core Copper Armoured Cable
  • 16 Sq Mm 3 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 752.32 / MeterGet Latest Price

Product Details:

Conductor Size16 sqmm
Cable Length500 m
Voltage Grade1.1KV
Conductor MaterialCopper
Insulation MaterialPVC
Armour TypeGI Steel Strip
Cable ShapeRound
Outer SheathPVC
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

2.5 Sqmm X 2 Core Copper Armoured Cable

2.5 Sqmm X 2 Core Copper Armoured Cable
  • 2.5 Sqmm X 2 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 117.62 / MeterGet Latest Price

Product Details:

Number of Cores2 Core
Size (Cross-Sectional Area)2.5 sq.mm
Armour TypeStrip Armoured
Insulation MaterialXLPE
Conductor MaterialCopper
Voltage Grade1.1 kV
Sheath TypePVC

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

2.5 Sqmm X 3 Core Copper Armoured Cable

2.5 Sqmm X 3 Core Copper Armoured Cable
  • 2.5 Sqmm X 3 Core Copper Armoured Cable
Ask For Price
Product Price :Get Latest Price

Product Details:

Conductor Size2.5 sqmm
Cable Length500 m
Voltage Grade1.1KV
Conductor MaterialCopper
Insulation MaterialXLPE
Armour TypeAluminium Strip
Cable ShapeRound
Outer SheathPVC
Core ColourStandard
StandardIS 7098

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

2.5 Sq Mm 4 Core Copper Armoured Cable

2.5 Sq Mm 4 Core Copper Armoured Cable
  • 2.5 Sq Mm 4 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 196.25 / MeterGet Latest Price

Product Details:

Number of Cores4 Core
Size (Cross-Sectional Area)2.5 sq.mm
Armour TypeStrip Armoured
Insulation MaterialXLPE
Conductor MaterialCopper
Voltage Grade1.1 kV
Sheath TypePVC

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

4 Sq Mm X 2 Core Copper Armoured Cable

4 Sq Mm X 2 Core Copper Armoured Cable
  • 4 Sq Mm X 2 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 163.54 / MeterGet Latest Price

Product Details:

Number of Cores2 Core
Size (Cross-Sectional Area)4 sq.mm
Armour TypeStrip Armoured
Insulation MaterialXLPE
Conductor MaterialCopper
Voltage Grade1.1 kV
Sheath TypePVC

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

4 Sq Mm X 3 Core Copper Armoured Cable

4 Sq Mm X 3 Core Copper Armoured Cable
  • 4 Sq Mm X 3 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 219.05 / MeterGet Latest Price

Product Details:

Number of Cores3 Core
Size (Cross-Sectional Area)4 sq.mm
Armour TypeStrip Armoured
Insulation MaterialXLPE
Conductor MaterialCopper
Voltage Grade1.1 kV
Sheath TypePVC

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

4 Sq Mm 4 Core Copper Armoured Cable

4 Sq Mm 4 Core Copper Armoured Cable
  • 4 Sq Mm 4 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 280.84 / MeterGet Latest Price

Product Details:

Number of Cores4 Core
Size (Cross-Sectional Area)4 sq.mm
Armour TypeStrip Armoured
Insulation MaterialXLPE
Conductor MaterialCopper
Voltage Grade1.1 kV
Sheath TypePVC

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

6 Sq Mm 2 Core Copper Armoured Cable

6 Sq Mm 2 Core Copper Armoured Cable
  • 6 Sq Mm 2 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 230.28 / MeterGet Latest Price

Product Details:

Number of Cores2 Core
Size (Cross-Sectional Area)6 sq.mm
Armour TypeStrip Armoured
Insulation MaterialXLPE
Conductor MaterialCopper
Voltage Grade1.1 kV
Sheath TypePVC

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

6 Sq Mm 4 Core Copper Armoured Cable

6 Sq Mm 4 Core Copper Armoured Cable
  • 6 Sq Mm 4 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 671.70 / MeterGet Latest Price

Product Details:

Number of Cores4 Core
Size (Cross-Sectional Area)6 sq.mm
Armour TypeStrip Armoured
Insulation MaterialXLPE
Conductor MaterialCopper
Voltage Grade1.1 kV
Sheath TypePVC

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

10 Sq Mm 2 Core Copper Armoured Cable

10 Sq Mm 2 Core Copper Armoured Cable
  • 10 Sq Mm 2 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 366.08 / MeterGet Latest Price

Product Details:

Number of Cores2 Core
Size (Cross-Sectional Area)10 sq.mm
Armour TypeStrip Armoured
Insulation MaterialXLPE
Conductor MaterialCopper
Voltage Grade1.1 kV
Sheath TypePVC

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

10 Sq Mm 4 Core Copper Armoured Cable

10 Sq Mm 4 Core Copper Armoured Cable
  • 10 Sq Mm 4 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 671.70 / MeterGet Latest Price

Product Details:

Number of Cores4 Core
Size (Cross-Sectional Area)10 sq.mm
Armour TypeStrip Armoured
Insulation MaterialXLPE
Conductor MaterialCopper
Voltage Grade1.1 kV
Sheath TypePVC

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

16 Sq Mm 2 Core Copper Armoured Cable

16 Sq Mm 2 Core Copper Armoured Cable
  • 16 Sq Mm 2 Core Copper Armoured Cable
Get Best Quote
Approx. Price: Rs 542.84 / MeterGet Latest Price

Product Details:

Number of Cores2 Core
Size (Cross-Sectional Area)16 sq.mm
Armour TypeStrip Armoured
Insulation MaterialXLPE
Conductor MaterialCopper
Voltage Grade1.1 kV
Sheath TypePVC

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested

16 Sq Mm 4 Core Copper Armour Cable

16 Sq Mm 4 Core Copper Armour Cable
  • 16 Sq Mm 4 Core Copper Armour Cable
Get Best Quote
Approx. Price: Rs 993.51 / MeterGet Latest Price

Product Details:

Number of Cores4 Core
Size (Cross-Sectional Area)16 sq.mm
Armour TypeStrip Armoured
Insulation MaterialXLPE
Conductor MaterialCopper
Voltage Grade1.1 kV
Sheath TypePVC

CAIS-7098 (Part-1) compliant cables feature EC grade aluminium or copper conductors with XLPE insulation. They offer advantages including higher current and short circuit ratings, better resistance to moisture and chemicals, and longer service life.

ConductorThe Conductor of the power cable is generally made from EC grade aluminum, and annealed high-conductivity copper is used for control cables. All conductors conform to IS: 8130:1984. Power Cables with copper conductors can also be supplied as per customer requirements. The conductor is solid/stranded/bunched as per requirements.InsulationXLPE (Cross-Linked Polyethylene)Laying UpThe cores are laid up with a suitable lay. The final layer always has a right-hand lay, i.e., if you look along the cable, the cores move to your right hand or clockwise.Inner SheathThe Laid-Up Cores shall be provided with an inner sheath applied either by extrusion or by wrapping. The fillers and inner sheath shall be on the following:
  • Unvulcanised Rubber
  • Thermoplastic Materials
Single-Core Cables do not have an inner sheath; this ensures that it is as circular as possible.ArmouringArmouring shall be applied over the insulation in case of single-core cables and over the inner sheath in case of twin, three, and multicore cables. The armour wires/strips shall be applied as closely as practicable. Where the calculated armouring below does not exceed 13mm. The armour shall consist of galvanised round steel wire, and where the calculated diameter below the armouring is greater than 13 mm, the armour shall consist of either galvanized round steel wire or galvanised steel strips.Outer SheathThe PVC covering over the armouring in case of armoured cables and over the inner sheath in case of unarmoured cables is called the outer sheath. IS: 1554 specifies the nominal and minimum thickness of outer sheath for unarmoured cables and only the minimum thickness of outer sheath for armoured cables. Types of PVC compounds for outer sheath:
  1. Outer sheath with type ST1 PVC compound as per IS: 5831, which is suitable for 70°C continuous operation.
  2. Outer sheath with type ST2 PVC compound as per IS: 5831, which is suitable for 85°C continuous operation.
The advantages of XLPE-insulated cables in comparison to PVC-insulated cables are as follows:A. Technical Advantages
  1. Longer service life
  2. Low Dielectric Losses
  3. Higher insulation resistance
  4. Higher resistance to moisture
  5. Better resistance to chemicals
  6. Better Resistance to surge currents
  7. XLPE is thermosetting in nature; therefore, it cannot be reprocessed
  8. Short circuit temperature for XLPE cables is 250°C, whereas for PVC it is 160°C
  9. Higher current rating, higher short circuit rating, approx. 1.2 times that of PVC
  10. Allowable continuous operating temperature for XLPE cables is 90°C, whereas it is only 70°C for PVC cables
B. Commercial Advantages
  1. Due to low specific gravity, XLPE cables are lighter than PVC cables.
  2. Capable of carrying high current through the same cross-sectional area as compared to PVC-insulated cables.
  3. Lower installation charges as the diameter of the cable is comparatively smaller with a smaller bending radius, requiring less space for laying cables.
Request
Callback
Yes! I am Interested
X

Explore More Products

View All Products
Tell Us What Are You Looking For ?




Reach Us
Abhishek Jain (Proprietor)
Lumens Electrical
73, Sanskrati Park, A B Road, Pigdember Rau
Rau - 453331, Indore, Madhya Pradesh, India
Get Directions

Call Us


Send E-mail